Item Control Unit
Model TeSys LUCA12BL
Brand Telemecanique
Main
range
TeSys
product name
TeSys U
device short name
LUCA
product or component type
Standard control unit
product specific application
Basic protection requirements for motor starters: overload and short-circuit
product compatibility
ASILUFC51
LUFN..
ASILUFC5
LUFC00
utilisation category
AC-41
AC-43
AC-44
motor power kW
9 kW at 690 V AC 50/60 Hz
5.5 kW at 400...440 V AC 50/60 Hz
5.5 kW at 500 V AC 50/60 Hz
thermal protection adjustment range
3...12 A
[Uc] control circuit voltage
24 V DC
thermal overload class
Class 10 - frequency limit: 40...60 Hz - temperature compensation: -25...70 °C - conforming to IEC 60947-6-2
Class 10 - frequency limit: 40...60 Hz - temperature compensation: -25...70 °C - conforming to UL 508
Complementary
main function available
Protection against phase failure and phase imbalance
Earth fault protection
Manual reset
Protection against overload and short-circuit
mounting mode
Plug-in
mounting location
Front side
control circuit voltage limits
20...27 V for DC circuit 24 V in operation
typical current consumption
130 mA at 24 V DC I maximum while closing with LUB12
220 mA at 24 V DC I maximum while closing with LUB32
60 mA at 24 V DC I rms sealed with LUB12
80 mA at 24 V DC I rms sealed with LUB32
operating time
35 ms opening with LUB12 for control circuit
35 ms opening with LUB32 for control circuit
70 ms closing with LUB12 for control circuit
70 ms closing with LUB32 for control circuit
load type
3-phase motor - cooling: self-cooled
tripping threshold
14.2 x Ir +/- 20 %
[Ui] rated insulation voltage
600 V conforming to CSA C22.2 No 14
600 V conforming to UL 508
690 V conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-6-2
safe separation of circuit
400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1
400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1
product weight
0.135 kg
Environment
heat dissipation
2 W for control circuit with LUB12
3 W for control circuit with LUB32
immunity to microbreaks
3 ms
immunity to voltage dips
70 P0 ms conforming to IEC 61000-4-11
standards
CSA C22.2 No 14 type E
EN 60947-6-2
IEC 60947-6-2
UL 508 type E with phase barrier